ISO & CE Certified • Global Supply Chain • Comprehensive Warranty
WhatsApp Us!
Request Quote!
0
Rotary Microtome ROM-02
Labotemp Rotary Microtome

Rotary Microtome ROM-02

Labotemp Rotary Microtome ROM-02 is a high-precision microtome machine designed for reliable tissue sectioning in histopathology, diagnostic, and research laboratories. As a fully automated rotary microtome, it produces uniform thin sections with an adjustable cut thickness range from 0.25 μm to 100 μm, supporting consistent serial sectioning for routine histology and advanced microscopy applications. The intelligent motor-driven specimen feed ensures smooth, controlled movement.

A rigid microtome blade holder supports standard disposable microtome blades and steel microtome knives, maintaining stable blade contact for clean sectioning. Automated specimen retraction, multiple cutting modes, remote control operation, and integrated safety features enhance workflow efficiency and user confidence compared to manual or sliding microtome systems.

Why choose Labotemp Rotary Microtome ROM-02?

✓ Consistent section quality: Precision automation maintains uniform section thickness.
✓ Reliable blade performance: Stable blade alignment supports clean, repeatable cuts.
✓ Efficient workflow: Programmable modes enable smooth, high-throughput operation.
✓ Operator comfort & safety: Automation reduces manual effort and improves control.

$14243
Datasheet

Specifications Rotary Microtome ROM-02

Section thickness setting range : 0.25–100 µm<br> 0.25–2.5 µm increment 0.25 µm<br> 2.5–5 µm increment 0.5 µm<br> 5–10 µm increment 1 µm<br> 10–30 µm increment 2 µm<br> 30–60 µm increment 5 µm<br> 60–100 µm increment 10 µm

Section thickness setting range
0.25–100 µm
0.25–2.5 µm increment 0.25 µm
2.5–5 µm increment 0.5 µm
5–10 µm increment 1 µm
10–30 µm increment 2 µm
30–60 µm increment 5 µm
60–100 µm increment 10 µm

Trimming thickness setting range : 1–600 µm<br> 1–10 µm increment 1 µm<br> 10–20 µm increment 2 µm<br> 20–50 µm increment 5 µm<br> 50–150 µm increment 10 µm<br> 50–600 µm increment 50 µm

Trimming thickness setting range
1–600 µm
1–10 µm increment 1 µm
10–20 µm increment 2 µm
20–50 µm increment 5 µm
50–150 µm increment 10 µm
50–600 µm increment 50 µm

Minimum setting of sectioning thickness : 0.25 µm

Minimum setting of sectioning thickness
0.25 µm

Specimen retraction setting range : 0–50 µm (0 is off); 10–15 µm, 5–50 µm (optional)

Specimen retraction setting range
0–50 µm (0 is off); 10–15 µm, 5–50 µm (optional)

Precision and error : ±1%

Precision and error
±1%

Maximum specimen size : 70×70 mm

Maximum specimen size
70×70 mm

Specimen horizontal feed : 25 mm

Specimen horizontal feed
25 mm

Specimen vertical feed : 70 mm

Specimen vertical feed
70 mm

Specimen clamp rotation : At any angle within 360°

Specimen clamp rotation
At any angle within 360°

Movement range of specimen holder base : 65 mm (front to back)

Movement range of specimen holder base
65 mm (front to back)

Specimen orientation system : XY-8°

Specimen orientation system
XY-8°

Feed speed adjust : 1500 µm/s – 3500 µm/s

Feed speed adjust
1500 µm/s – 3500 µm/s

Voltage and frequency : AC 220 V ±10%, 50 Hz / 110V 60Hz (Standard)

Voltage and frequency
AC 220 V ±10%, 50 Hz / 110V 60Hz (Standard)

Power : 150 W

Power
150 W

Size (W×D×H) : 580×475×340 mm

Size (W×D×H)
580×475×340 mm

Net weight : 33 kg

Net weight
33 kg

Gross weight : 49 kg

Gross weight
49 kg

Package size : 690x590x500 mm

Package size
690x590x500 mm

Features Rotary Microtome ROM-02

  • Advanced Full-Automatic ➤ Advanced Full-Automatic
  • Intelligent system for manual or automatic sectioning ➤ Intelligent system for manual or automatic sectioning
  • Multi-function drive for sectioning, trimming, and fast movement ➤ Multi-function drive for sectioning, trimming, and fast movement
  • Continuously adjustable cutting speed ➤ Continuously adjustable cutting speed
  • Safety system with emergency braking and protection ➤ Safety system with emergency braking and protection
  • Quick change between paraffin block and cassette clamps ➤ Quick change between paraffin block and cassette clamps
  • Digital display for thickness, count, and speed ➤ Digital display for thickness, count, and speed
  • Lockable, precisely balanced hand wheel ➤ Lockable, precisely balanced hand wheel

Applications Rotary Microtome ROM-02

  • ROM-02 is used for routine histopathology sectioning, pathology and diagnostic laboratories, medical and clinical research laboratories, academic and teaching institutions, and tissue sample preparation for microscopic examination ➤ ROM-02 is used for routine histopathology sectioning, pathology and diagnostic laboratories, medical and clinical research laboratories, academic and teaching institutions, and tissue sample preparation for microscopic examination

Standard Accessories

  • External control panel ➤ External control panel
  • Standard specimen clamp ➤ Standard specimen clamp
  • Universal specimen clamp ➤ Universal specimen clamp

Optional Accessories

  • High-profile blades – 10 boxes ➤ High-profile blades – 10 boxes
  • Low-profile blades – 10 boxes ➤ Low-profile blades – 10 boxes
  • Foot Switch ➤ Foot Switch