ISO & CE Certified • Global Supply Chain • Comprehensive Warranty
WhatsApp Us!
Request Quote!
0
Pulse Vacuum Sterilizer LPS-102
Pulse Vacuum Sterilizer

Pulse Vacuum Sterilizer LPS-102

Labotemp Pulse Vacuum Sterilizer LPS-102 features a 250L stainless steel chamber, operating temperature up to 139°C, vacuum level up to -96 kPa, and precision temperature control for reliable sterilization in hospitals, pharmaceutical production, biotechnology facilities, and research laboratories. This laboratory autoclave uses advanced pulse vacuum sterilization technology to improve steam penetration into porous materials, surgical instruments, glassware, textiles, and laboratory equipment while supporting efficient moisture removal through vacuum drying cycles. The jacketed chamber structure enhances thermal stability and ensures uniform steam distribution during continuous sterilization workflows.

The automatic sliding door, inflatable sealing system, and intelligent vacuum control improve operational safety and chamber reliability during repeated sterilization processes. Multiple protection systems including over-pressure alarms, low-water protection, automatic shutdown, and vacuum leakage monitoring support stable and secure laboratory performance. Energy-efficient steam utilization, durable SS304 chamber construction, and programmable sterilization cycles make this sterilizer suitable for pharmaceutical processing, microbiology laboratories, medical facilities, and sterile research applications.

Why Choose Labotemp Pulse Vacuum Sterilizer LPS-102?


✓ PLC Touch-Screen Control: Automated cycle management with real-time monitoring
✓ Advanced Safety System: Multiple alarms, interlocks, and vacuum protection features
✓ Efficient Vacuum Drying: Improved post-sterilization drying and workflow efficiency

$19403
Datasheet

Specifications Pulse Vacuum Sterilizer LPS-102

General Specifications

Capacity : 250 L

Capacity
250 L

Maximum Operating Temperature : 139°C

Maximum Operating Temperature
139°C

Design Temperature : 150°C

Design Temperature
150°C
Sterilization Parameters

Maximum Operating Pressure : 0.25 MPa

Maximum Operating Pressure
0.25 MPa

Chamber Design Pressure : -0.1 / 0.3 MPa

Chamber Design Pressure
-0.1 / 0.3 MPa

Jacket Design Pressure : 0.3 MPa

Jacket Design Pressure
0.3 MPa

Generator Design Pressure : 1.0 MPa

Generator Design Pressure
1.0 MPa

Temperature Accuracy : 0.1°C

Temperature Accuracy
0.1°C

Pressure Accuracy : 0.1 kPa

Pressure Accuracy
0.1 kPa

Sterilization Temperature Control Accuracy : ±1°C

Sterilization Temperature Control Accuracy
±1°C

Temperature Uniformity : ±1°C

Temperature Uniformity
±1°C

Negative Pressure Pulsating Vacuum : -80–0 kPa

Negative Pressure Pulsating Vacuum
-80–0 kPa

Across the Pressure Pulsation : -80–80 kPa

Across the Pressure Pulsation
-80–80 kPa

Positive Pressure Pulse : 0–9 times

Positive Pressure Pulse
0–9 times

Maximum Vacuum : -96 kPa

Maximum Vacuum
-96 kPa
Operation

Power Supply : 380 V, 220 V, 50 Hz

Power Supply
380 V, 220 V, 50 Hz

Power Rating : 2 kW + (20 kW)

Power Rating
2 kW + (20 kW)

Chamber Relief Valve : 0.28 MPa

Chamber Relief Valve
0.28 MPa

Jacket Relief Valve : 0.28 MPa

Jacket Relief Valve
0.28 MPa

Steam Consumption : 16 kg/Cycle

Steam Consumption
16 kg/Cycle

Water Consumption : 120 kg/Cycle

Water Consumption
120 kg/Cycle
Physical Dimensions

Chamber Size (W × H × D) : 550 × 550 × 845 mm

Chamber Size (W × H × D)
550 × 550 × 845 mm

Overall Dimensions (L × W × H) : 1150 × 1255 × 1800 mm

Overall Dimensions (L × W × H)
1150 × 1255 × 1800 mm

Package Size : 1450 × 1350 × 2200 mm

Package Size
1450 × 1350 × 2200 mm

Package Size (transfer vehicles) : 1450 × 1150 × 1020 mm

Package Size (transfer vehicles)
1450 × 1150 × 1020 mm

Net Weight : 795 kg

Net Weight
795 kg

Gross Weight : 883 kg

Gross Weight
883 kg

Features Pulse Vacuum Sterilizer LPS-102

  • Multi-Level Alarm  ➤ Multi-Level Alarm 
  • Pulse vacuum operation supports improved cycle consistency ➤ Pulse vacuum operation supports improved cycle consistency
  • Uniform heat distribution for dependable sterilization performance ➤ Uniform heat distribution for dependable sterilization performance
  • Automatic process sequencing reduces operator intervention ➤ Automatic process sequencing reduces operator intervention
  • Industrial-grade chamber construction for long service life ➤ Industrial-grade chamber construction for long service life
  • Multi-stage pressure management for stable operation ➤ Multi-stage pressure management for stable operation
  • Fast chamber evacuation and efficient post-cycle drying ➤ Fast chamber evacuation and efficient post-cycle drying
  • User-configurable operating parameters for process flexibility ➤ User-configurable operating parameters for process flexibility
  • Continuous-duty design for high-throughput sterilization environments ➤ Continuous-duty design for high-throughput sterilization environments
  • Smooth internal chamber structure for easier cleaning ➤ Smooth internal chamber structure for easier cleaning
  • Integrated operational diagnostics for system monitoring ➤ Integrated operational diagnostics for system monitoring
  • Optimized utility consumption for efficient daily use ➤ Optimized utility consumption for efficient daily use
  • Stable chamber conditions during repeated sterilization cycles ➤ Stable chamber conditions during repeated sterilization cycles

Applications Pulse Vacuum Sterilizer LPS-102

  • LPS-102 is suitable for steam sterilization of surgical instruments, laboratory glassware, textiles, rubber materials, dressing packs, liquid media, and heat-resistant medical devices in hospitals, CSSD departments, pharmaceutical manufacturing, biotechnology facilities, research laboratories, and quality control environments ➤ LPS-102 is suitable for steam sterilization of surgical instruments, laboratory glassware, textiles, rubber materials, dressing packs, liquid media, and heat-resistant medical devices in hospitals, CSSD departments, pharmaceutical manufacturing, biotechnology facilities, research laboratories, and quality control environments
  • Supports validated sterilization workflows requiring automated process monitoring, vacuum drying, traceable records, and consistent temperature-pressure control ➤ Supports validated sterilization workflows requiring automated process monitoring, vacuum drying, traceable records, and consistent temperature-pressure control