Labotemp Pulse Vacuum Sterilizer LPS-101 features a 120L stainless steel chamber, sterilization temperature up to 139°C, vacuum drying system, and PLC-based automatic control for reliable steam sterilization in hospitals, pharmaceutical facilities, CSSD units, and research laboratories. This laboratory autoclave supports pulse vacuum air removal for deeper steam penetration into surgical instruments, glassware, textiles, rubber items, dressing materials, and laboratory tools requiring high sterilization efficiency and controlled drying performance. The jacketed chamber structure improves heat preservation while helping maintain stable temperature distribution throughout the sterilization cycle.
Built for continuous institutional operation, the LPS-101 combines Siemens PLC touch-screen control, automatic door safety interlock, intelligent vacuum management, and multi-level alarm protection for dependable daily performance. Flash vacuum drying technology helps reduce residual moisture after sterilization, while the reinforced chamber structure and inflatable silicone sealing system improve airtight reliability during repeated cycles. Automatic process monitoring, low-noise vacuum operation, and efficient steam utilization support energy-efficient sterilization workflows across demanding laboratory and medical environments.
Why Choose Labotemp Pulse Vacuum Sterilizer LPS-101?
✓ Pulse Vacuum Sterilization: Efficient steam penetration for porous and wrapped materials
✓ Intelligent PLC Control: Fully automatic touch-screen cycle management
✓ Reliable Safety Protection: Door interlocks, alarms, and pressure monitoring for secure operation
| General Specifications | |
|
Capacity : 120 L Capacity |
120 L |
|
Maximum Operating Temperature : 139°C Maximum Operating Temperature |
139°C |
|
Design Temperature : 150°C Design Temperature |
150°C |
| Sterilization Parameters | |
|
Maximum Operating Pressure : 0.25 MPa Maximum Operating Pressure |
0.25 MPa |
|
Maximum Vacuum : -96 kPa Maximum Vacuum |
-96 kPa |
|
Positive Pressure Pulse : 0–9 times Positive Pressure Pulse |
0–9 times |
|
Across Pressure Pulsation : -80–80 kPa Across Pressure Pulsation |
-80–80 kPa |
|
Negative Pressure Pulsating Vacuum : -80–0 kPa Negative Pressure Pulsating Vacuum |
-80–0 kPa |
|
Temperature Uniformity : ±1°C Temperature Uniformity |
±1°C |
|
Sterilization Temperature Control Accuracy : ±1°C Sterilization Temperature Control Accuracy |
±1°C |
|
Pressure Accuracy : 0.1 kPa Pressure Accuracy |
0.1 kPa |
|
Temperature Accuracy : 0.1°C Temperature Accuracy |
0.1°C |
|
Generator Design Pressure : 1.0 MPa Generator Design Pressure |
1.0 MPa |
|
Jacket Design Pressure : 0.3 MPa Jacket Design Pressure |
0.3 MPa |
|
Chamber Design Pressure : -0.1 / 0.3 MPa Chamber Design Pressure |
-0.1 / 0.3 MPa |
| Operation | |
|
Power Supply : 380 V, 220 V, 50 Hz Power Supply |
380 V, 220 V, 50 Hz |
|
Power : 2 kW + (12 kW) Power |
2 kW + (12 kW) |
|
Jacket Relief Valve : 0.28 MPa Jacket Relief Valve |
0.28 MPa |
|
Chamber Relief Valve : 0.28 MPa Chamber Relief Valve |
0.28 MPa |
|
Water Consumption : 70 kg/cycle Water Consumption |
70 kg/cycle |
|
Steam Consumption : 10 kg/cycle Steam Consumption |
10 kg/cycle |
| Physical Dimensions | |
|
Overall Dimensions (L × W × H) : 1000 × 1190 × 1700 mm Overall Dimensions (L × W × H) |
1000 × 1190 × 1700 mm |
|
Chamber Size (W × H × D) : 450 × 450 × 650 mm Chamber Size (W × H × D) |
450 × 450 × 650 mm |
|
Package Size : 1100 × 1270 × 2200 mm Package Size |
1100 × 1270 × 2200 mm |
|
Package Size (transfer vehicles) : 1680 × 1050 × 1200 mm Package Size (transfer vehicles) |
1680 × 1050 × 1200 mm |
|
Net Weight : 300 kg Net Weight |
300 kg |
|
Gross Weight : 350 kg Gross Weight |
350 kg |