Pulse Vacuum Sterilizer LPS-102

A4 preview · Your PDF uses these same pages.

Pulse Vacuum Sterilizer LPS-102
Product Catalog

Pulse Vacuum Sterilizer LPS-102

LPS-102

Get to know

Why choose
Pulse Vacuum Sterilizer LPS-102?

  1. 1
    Multi-Level Alarm 
  2. 2
    Pulse vacuum operation supports improved cycle consistency
  3. 3
    Uniform heat distribution for dependable sterilization performance
LPS-102

Pulse Vacuum Sterilizer

Pulse Vacuum Sterilizer LPS-102
Pulse Vacuum Sterilizer LPS-102
Overview

Product
Description

Product overview

Pulse Vacuum Sterilizer LPS-102

Labotemp Pulse Vacuum Sterilizer LPS-102 features a 250L stainless steel chamber, operating temperature up to 139°C, vacuum level up to -96 kPa, and precision temperature control for reliable sterilization in hospitals, pharmaceutical production, biotechnology facilities, and research laboratories. This laboratory autoclave uses advanced pulse vacuum sterilization technology to improve steam penetration into porous materials, surgical instruments, glassware, textiles, and laboratory equipment while supporting efficient moisture removal through vacuum drying cycles. The jacketed chamber structure enhances thermal stability and ensures uniform steam distribution during continuous sterilization workflows.

The automatic sliding door, inflatable sealing system, and intelligent vacuum control improve operational safety and chamber reliability during repeated sterilization processes. Multiple protection systems including over-pressure alarms, low-water protection, automatic shutdown, and vacuum leakage monitoring support stable and secure laboratory performance. Energy-efficient steam utilization, durable SS304 chamber construction, and programmable sterilization cycles make this sterilizer suitable for pharmaceutical processing, microbiology laboratories, medical facilities, and sterile research applications.

Why Choose Labotemp Pulse Vacuum Sterilizer LPS-102?


✓ PLC Touch-Screen Control: Automated cycle management with real-time monitoring
✓ Advanced Safety System: Multiple alarms, interlocks, and vacuum protection features
✓ Efficient Vacuum Drying: Improved post-sterilization drying and workflow efficiency

Technical data · LPS-102

Complete Specifications

Pulse Vacuum Sterilizer LPS-102
No.SpecificationValue
General Specifications
1Capacity250 L
2Maximum Operating Temperature139°C
3Design Temperature150°C
Sterilization Parameters
4Maximum Operating Pressure0.25 MPa
5Chamber Design Pressure-0.1 / 0.3 MPa
6Jacket Design Pressure0.3 MPa
7Generator Design Pressure1.0 MPa
8Temperature Accuracy0.1°C
9Pressure Accuracy0.1 kPa
10Sterilization Temperature Control Accuracy±1°C
11Temperature Uniformity±1°C
12Negative Pressure Pulsating Vacuum-80–0 kPa
13Across the Pressure Pulsation-80–80 kPa
14Positive Pressure Pulse0–9 times
15Maximum Vacuum-96 kPa
Operation
16Power Supply380 V, 220 V, 50 Hz
17Power Rating2 kW + (20 kW)
18Chamber Relief Valve0.28 MPa
19Jacket Relief Valve0.28 MPa
20Steam Consumption16 kg/Cycle
21Water Consumption120 kg/Cycle
Physical Dimensions
22Chamber Size (W × H × D)550 × 550 × 845 mm
23Overall Dimensions (L × W × H)1150 × 1255 × 1800 mm
24Package Size1450 × 1350 × 2200 mm
25Package Size (transfer vehicles)1450 × 1150 × 1020 mm
26Net Weight795 kg
27Gross Weight883 kg
What's included

Features

  1. 1
    Multi-Level Alarm 
  2. 2
    Pulse vacuum operation supports improved cycle consistency
  3. 3
    Uniform heat distribution for dependable sterilization performance
  4. 4
    Automatic process sequencing reduces operator intervention
  5. 5
    Industrial-grade chamber construction for long service life
  6. 6
    Multi-stage pressure management for stable operation
  7. 7
    Fast chamber evacuation and efficient post-cycle drying
  8. 8
    User-configurable operating parameters for process flexibility
  9. 9
    Continuous-duty design for high-throughput sterilization environments
  10. 10
    Smooth internal chamber structure for easier cleaning
  11. 11
    Integrated operational diagnostics for system monitoring
  12. 12
    Optimized utility consumption for efficient daily use
  13. 13
    Stable chamber conditions during repeated sterilization cycles
Where it's used

Applications

Hospitals & CSSD Facilities: Suitable for high-volume sterilization of compatible surgical instruments, dressing packs, textiles, rubber materials, laboratory glassware, and other heat- and moisture-resistant medical items.

Pharmaceutical Manufacturing: Supports sterilization of compatible production materials, containers, laboratory instruments, glassware, and other heat-resistant items requiring controlled steam sterilization.

Biotechnology Facilities: Suitable for sterilization workflows involving compatible laboratory equipment, reusable instruments, glassware, and other heat-resistant materials.

Microbiology & Research Laboratories: Designed for sterilizing laboratory instruments, glassware, culture-related materials, and other compatible loads requiring vacuum-assisted steam penetration.

Healthcare Facilities: Supports reliable sterilization of compatible medical and surgical materials requiring controlled steam processing, effective air removal, and drying.

Research Laboratories: Suitable for institutions requiring repeatable and traceable sterilization cycles with automated process monitoring and vacuum drying.

High-Volume Sterilization: The 250 L chamber is well suited to facilities requiring efficient batch processing, consistent sterilization, and reliable drying for larger compatible loads.

Pulse Vacuum Sterilizer LPS-102