Platelet Incubator With Agitator LPA-105
Platelet Incubator With Agitator LPA-105

Platelet Incubator With Agitator LPA-105

Labotemp Platelet Incubator with Agitator LPA-105 is a precision-controlled platelet incubator designed for safe preservation of platelet concentrates in blood banks, hospitals, transfusion centers, and clinical laboratories. Featuring a 20–40 blood bag capacity, 22 ±2°C temperature range, ±0.1°C temperature accuracy, and continuous horizontal agitation at 60 ±5 cycles/min with a 50 mm oscillation amplitude, it maintains optimal storage conditions required for platelet viability. The microprocessor-controlled system, IPS touchscreen display, and multiple temperature monitoring methods ensure accurate regulation, while the air-cooled R134a refrigeration system delivers stable, energy-efficient performance. Although this system provides continuous shaking similar to a shaking incubator, it is specifically engineered for platelet preservation rather than general laboratory incubation or an orbital shaker incubator.

Built for reliable daily operation, the LPA-105 features UV disinfection, automatic defrost, anti-slip drawer shelves, double-layer tempered glass door, and quiet lockable casters for convenient use. Comprehensive audible and visual alarms monitor high/low temperature, abnormal shutdown, agitator faults, and door status to protect valuable platelet inventories. Optional wireless monitoring, barcode scanning, UPS backup, and LIS connectivity further enhance traceability and workflow efficiency. Its durable construction, precise temperature control, and dependable agitation system make it an ideal solution for continuous platelet storage in modern healthcare and laboratory environments.

Why Choose Labotemp Platelet Incubator with Agitator LPA-105?

✓ Precision Platelet Storage: Maintains 22 ±2°C with continuous horizontal agitation for platelet viability.
✓ Advanced Safety Monitoring: Multi-level alarms protect against temperature, agitator, power, and door abnormalities.
✓Efficient Laboratory Operation: UV sterilization, automatic defrost, and energy-efficient R134a cooling reduce maintenance.

$6587
Datasheet

Specifications Platelet Incubator With Agitator LPA-105

Model : LPA-105

Model
LPA-105

Temperature Control Method : Digital Signal Detection, Microprocessor Control

Temperature Control Method
Digital Signal Detection, Microprocessor Control

Temperature Range : 22 ±2°C

Temperature Range
22 ±2°C

Temperature Accuracy : ±0.1°C

Temperature Accuracy
±0.1°C

Ambient Temperature : 5–35°C

Ambient Temperature
5–35°C

Alarm Temperature : <20°C, >24°C, abnormal shutdown & power failure alarm

Alarm Temperature
<20°C, >24°C, abnormal shutdown & power failure alarm

Oscillation Frequency : 60 ±5 cycles/min

Oscillation Frequency
60 ±5 cycles/min

Oscillation Amplitude : 50 mm

Oscillation Amplitude
50 mm

Working Mode : Continuous left-right horizontal reciprocating agitation

Working Mode
Continuous left-right horizontal reciprocating agitation

Storage Capacity : 20 Blood Bags (Optimal), 40 Blood Bags (Maximum)

Storage Capacity
20 Blood Bags (Optimal), 40 Blood Bags (Maximum)

Heating Consumption : 200 W

Heating Consumption
200 W

Refrigeration Consumption : 300 W

Refrigeration Consumption
300 W

Refrigerant : Air-cooled R134a

Refrigerant
Air-cooled R134a

Power Supply : AC220V, 50/60Hz

Power Supply
AC220V, 50/60Hz

Dimensions (W × D × H) : 690 × 680 × 1050 mm

Dimensions (W × D × H)
690 × 680 × 1050 mm

Display : IPS High-Definition Touchscreen

Display
IPS High-Definition Touchscreen

Disinfection : UV Sterilization

Disinfection
UV Sterilization

Defrost : Automatic

Defrost
Automatic

Mobility : Silent Lockable Casters

Mobility
Silent Lockable Casters

Gross Weight : 100 kg

Gross Weight
100 kg

Package Size : 835 x 770 x 1275 mm

Package Size
835 x 770 x 1275 mm

Features Platelet Incubator With Agitator LPA-105

  • Smart Alarm System ➤ Smart Alarm System
  • Microprocessor-controlled temperature regulation with IPS high-definition touchscreen. ➤ Microprocessor-controlled temperature regulation with IPS high-definition touchscreen.
  • Maintains 22 ±2°C storage temperature with ±0.1°C control accuracy. ➤ Maintains 22 ±2°C storage temperature with ±0.1°C control accuracy.
  • Continuous horizontal reciprocating agitation at 60 ±5 cycles/min with 50 mm oscillation amplitude. ➤ Continuous horizontal reciprocating agitation at 60 ±5 cycles/min with 50 mm oscillation amplitude.
  • Multiple temperature monitoring methods for reliable temperature control. ➤ Multiple temperature monitoring methods for reliable temperature control.
  • UV disinfection and chamber lighting improve hygiene and sample visibility. ➤ UV disinfection and chamber lighting improve hygiene and sample visibility.
  • Audible and visual alarms for high/low temperature, abnormal shutdown, agitator malfunction, and door-open status. ➤ Audible and visual alarms for high/low temperature, abnormal shutdown, agitator malfunction, and door-open status.
  • Air-cooled R134a refrigeration system for stable, energy-efficient cooling. ➤ Air-cooled R134a refrigeration system for stable, energy-efficient cooling.
  • Automatic defrost minimizes maintenance. ➤ Automatic defrost minimizes maintenance.
  • Double-layer tempered glass door provides excellent thermal insulation. ➤ Double-layer tempered glass door provides excellent thermal insulation.
  • Anti-slip coated storage shelves securely hold platelet bags. ➤ Anti-slip coated storage shelves securely hold platelet bags.
  • Quiet lockable casters enable convenient movement. ➤ Quiet lockable casters enable convenient movement.
  • Leakage protection enhances operational safety. ➤ Leakage protection enhances operational safety.
  • Optional wireless monitoring, barcode scanner, UPS backup, and LIS connectivity for workflow management. ➤ Optional wireless monitoring, barcode scanner, UPS backup, and LIS connectivity for workflow management.

Applications Platelet Incubator With Agitator LPA-105

  • Controlled storage and preservation of platelet concentrates at 22 ±2°C ➤ Controlled storage and preservation of platelet concentrates at 22 ±2°C
  • Blood banks and transfusion medicine departments requiring continuous platelet agitation ➤ Blood banks and transfusion medicine departments requiring continuous platelet agitation
  • Hospital blood centers and clinical laboratories storing platelet products ➤ Hospital blood centers and clinical laboratories storing platelet products
  • Hematology and pathology laboratories maintaining platelet viability before transfusion ➤ Hematology and pathology laboratories maintaining platelet viability before transfusion
  • Blood component processing facilities requiring monitored platelet preservation and traceability ➤ Blood component processing facilities requiring monitored platelet preservation and traceability
  • Healthcare environments complying with regulated platelet storage protocols ➤ Healthcare environments complying with regulated platelet storage protocols

Standard Accessories

  • Wireless monitoring system ➤ Wireless monitoring system