Nanodrop Spectrophotometer NSP-01
Labotemp Nanodrop Spectrophotometer
Labotemp Nanodrop Spectrophotometer

Nanodrop Spectrophotometer NSP-01

Labotemp Nanodrop Spectrophotometer NSP-01 is a micro-volume spectrophotometer designed for rapid and accurate quantification of nucleic acids, proteins and other biomolecules in modern laboratories. The system requires only 0.5–2 µl sample volume, enabling direct measurement without dilution while preserving valuable samples. With a 190–900 nm wavelength range and 1 nm wavelength accuracy, it delivers reliable absorbance measurements for DNA, RNA and protein analysis. The advanced optical system with automatic path length switching (0.02–1 mm) ensures precise detection across both high and low concentration samples.

The instrument integrates a 2048-unit CMOS linear array detector and xenon flash lamp to provide stable measurements with testing completed in less than 5 seconds. It also supports OD600 detection for monitoring bacterial and yeast cell growth. The durable stainless steel and quartz sample pedestal allows easy cleaning and long-term reliability. Its compact design makes it suitable for molecular biology research, biotechnology laboratories, clinical diagnostics and pharmaceutical testing.

Why Choose Nanodrop Spectrophotometer NSP-01?
✓ Micro-Volume Measurement: Measures DNA, RNA and proteins with just 0.5 µl sample without dilution.
✓ Broad Detection Range: 190–900 nm wavelength range with automatic path switching for different sample concentrations.
✓ ISO & CE Compliant: Built to ISO and CE standards for reliable and safe laboratory performance.
 

$9480
Datasheet

Specifications Nanodrop Spectrophotometer NSP-01

Minimum Sample Size : 0.5 µl

Minimum Sample Size
0.5 µl

Wavelength Range : 190 – 900 nm

Wavelength Range
190 – 900 nm

Wavelength Accuracy : 1 nm

Wavelength Accuracy
1 nm

Wavelength Resolution : 1 nm

Wavelength Resolution
1 nm

Optical Path Length : 0.02 / 0.05 / 0.1 / 0.5 / 1 mm (automatic switching)

Optical Path Length
0.02 / 0.05 / 0.1 / 0.5 / 1 mm (automatic switching)

Absorbance Accuracy : ±1% (0.76 at 260 nm)

Absorbance Accuracy
±1% (0.76 at 260 nm)

Absorbance Resolution : 0.002 Abs (at 1 mm path length)

Absorbance Resolution
0.002 Abs (at 1 mm path length)

Absorbance Range : 0 – 750 A (10 mm equivalent)

Absorbance Range
0 – 750 A (10 mm equivalent)

OD600 Absorbance Range : 0 – 4.000 Abs

OD600 Absorbance Range
0 – 4.000 Abs

OD600 Stability : [0–3] ≤0.5%, [3–4] ≤2%

OD600 Stability
[0–3] ≤0.5%, [3–4] ≤2%

OD600 Repeatability : [0–3] ≤0.5%, [3–4] ≤2%

OD600 Repeatability
[0–3] ≤0.5%, [3–4] ≤2%

Nucleic Acid Detection Range : 1.5 – 37500 ng/µl (dsDNA), lower limit 1.5 ng/µl

Nucleic Acid Detection Range
1.5 – 37500 ng/µl (dsDNA), lower limit 1.5 ng/µl

Protein Detection Range : 0.05 – 1110 mg/ml (BSA), 0.03 – 540 mg/ml (IgG)

Protein Detection Range
0.05 – 1110 mg/ml (BSA), 0.03 – 540 mg/ml (IgG)

Sample Pedestal Material : 304 Stainless Steel and Quartz

Sample Pedestal Material
304 Stainless Steel and Quartz

Measurement Time : < 5 seconds

Measurement Time
< 5 seconds

Detector : 2048 unit CMOS linear array sensor

Detector
2048 unit CMOS linear array sensor

Light Source : Xenon Flash Lamp

Light Source
Xenon Flash Lamp

Dimensions (W × D × H) : 310 × 221 × 176 mm

Dimensions (W × D × H)
310 × 221 × 176 mm

Package Size : 320 × 380 × 330 mm

Package Size
320 × 380 × 330 mm

Gross Weight : 9kg

Gross Weight
9kg

Net Weight : 5.2kg

Net Weight
5.2kg

Features Nanodrop Spectrophotometer NSP-01

  • Rapid Sample Testing ➤ Rapid Sample Testing
  • Micro-volume sample testing requiring only 0.5–2 µl sample for quick measurements. ➤ Micro-volume sample testing requiring only 0.5–2 µl sample for quick measurements.
  • Wide detection capability, offering significantly broader concentration range than traditional spectrophotometers. ➤ Wide detection capability, offering significantly broader concentration range than traditional spectrophotometers.
  • No sample dilution required for most measurements, enabling direct and efficient testing. ➤ No sample dilution required for most measurements, enabling direct and efficient testing.
  • Full wavelength coverage with 190–900 nm scanning and 1 nm accuracy for reliable analysis. ➤ Full wavelength coverage with 190–900 nm scanning and 1 nm accuracy for reliable analysis.
  • Automatic optical path switching allowing precise measurement across varying sample concentrations. ➤ Automatic optical path switching allowing precise measurement across varying sample concentrations.
  • OD600 detection function for monitoring bacterial, yeast and microbial cell growth. ➤ OD600 detection function for monitoring bacterial, yeast and microbial cell growth.
  • Fast measurement time (&lt;5 seconds) for rapid laboratory workflows. ➤ Fast measurement time (<5 seconds) for rapid laboratory workflows.
  • Compact and portable design suitable for laboratory benches and on-site testing. ➤ Compact and portable design suitable for laboratory benches and on-site testing.
  • Built-in thermal printer and large data storage with USB export for easy data management. ➤ Built-in thermal printer and large data storage with USB export for easy data management.
  • Intelligent operation system enabling simple and efficient measurement processes. ➤ Intelligent operation system enabling simple and efficient measurement processes.

Applications Nanodrop Spectrophotometer NSP-01

  • DNA &amp; RNA Quantification: Accurate measurement of nucleic acid concentration for PCR, sequencing, cloning and other molecular biology workflows DNA & RNA Quantification
    Accurate measurement of nucleic acid concentration for PCR, sequencing, cloning and other molecular biology workflows
  • Protein Analysis: Determination of protein concentration in biochemical and proteomics research Protein Analysis
    Determination of protein concentration in biochemical and proteomics research
  • Microbial Growth Monitoring: OD600 measurement for analyzing bacterial and yeast culture growth in microbiology laboratories Microbial Growth Monitoring
    OD600 measurement for analyzing bacterial and yeast culture growth in microbiology laboratories
  • Clinical &amp; Diagnostic Research: Used in clinical laboratories for biomolecular analysis and disease research studies Clinical & Diagnostic Research
    Used in clinical laboratories for biomolecular analysis and disease research studies
  • Environmental &amp; Food Testing: Detection and analysis of biological samples in environmental monitoring and food safety laboratories Environmental & Food Testing
    Detection and analysis of biological samples in environmental monitoring and food safety laboratories