ISO & CE Certified • Global Supply Chain • Comprehensive Warranty
WhatsApp Us!
Request Quote!
0

Nanodrop Spectrophotometer NSP-01

A4 preview · Your PDF uses these same pages.

Nanodrop Spectrophotometer NSP-01
Product Catalog

Nanodrop Spectrophotometer NSP-01

NSP-01

Get to know

Why choose
Nanodrop Spectrophotometer NSP-01?

  1. 1
    Rapid Sample Testing
  2. 2
    Micro-volume sample testing requiring only 0.5–2 µl sample for quick measurements.
  3. 3
    Wide detection capability, offering significantly broader concentration range than traditional spectrophotometers.
NSP-01

Spectroscopy Instruments

Nanodrop Spectrophotometer NSP-01
Nanodrop Spectrophotometer NSP-01
Overview

Product
Description

Product overview

Nanodrop Spectrophotometer NSP-01

Labotemp Nanodrop Spectrophotometer NSP-01 is a micro-volume spectrophotometer designed for rapid and accurate quantification of nucleic acids, proteins and other biomolecules in modern laboratories. The system requires only 0.5–2 µl sample volume, enabling direct measurement without dilution while preserving valuable samples. With a 190–900 nm wavelength range and 1 nm wavelength accuracy, it delivers reliable absorbance measurements for DNA, RNA and protein analysis. The advanced optical system with automatic path length switching (0.02–1 mm) ensures precise detection across both high and low concentration samples.

The instrument integrates a 2048-unit CMOS linear array detector and xenon flash lamp to provide stable measurements with testing completed in less than 5 seconds. It also supports OD600 detection for monitoring bacterial and yeast cell growth. The durable stainless steel and quartz sample pedestal allows easy cleaning and long-term reliability. Its compact design makes it suitable for molecular biology research, biotechnology laboratories, clinical diagnostics and pharmaceutical testing.

Why Choose Nanodrop Spectrophotometer NSP-01?
✓ Micro-Volume Measurement: Measures DNA, RNA and proteins with just 0.5 µl sample without dilution.
✓ Broad Detection Range: 190–900 nm wavelength range with automatic path switching for different sample concentrations.
✓ ISO & CE Compliant: Built to ISO and CE standards for reliable and safe laboratory performance.
 

Technical data · NSP-01

Complete Specifications

Nanodrop Spectrophotometer NSP-01
No.SpecificationValue
1Minimum Sample Size0.5 µl
2Wavelength Range190 – 900 nm
3Wavelength Accuracy1 nm
4Wavelength Resolution1 nm
5Optical Path Length0.02 / 0.05 / 0.1 / 0.5 / 1 mm (automatic switching)
6Absorbance Accuracy±1% (0.76 at 260 nm)
7Absorbance Resolution0.002 Abs (at 1 mm path length)
8Absorbance Range0 – 750 A (10 mm equivalent)
9OD600 Absorbance Range0 – 4.000 Abs
10OD600 Stability[0–3] ≤0.5%, [3–4] ≤2%
11OD600 Repeatability[0–3] ≤0.5%, [3–4] ≤2%
12Nucleic Acid Detection Range1.5 – 37500 ng/µl (dsDNA), lower limit 1.5 ng/µl
13Protein Detection Range0.05 – 1110 mg/ml (BSA), 0.03 – 540 mg/ml (IgG)
14Sample Pedestal Material304 Stainless Steel and Quartz
15Measurement Time< 5 seconds
16Detector2048 unit CMOS linear array sensor
17Light SourceXenon Flash Lamp
18Dimensions (W × D × H)310 × 221 × 176 mm
19Package Size320 × 380 × 330 mm
20Gross Weight 9kg
21Net Weight 5.2kg
What's included

Features

  1. 1
    Rapid Sample Testing
  2. 2
    Micro-volume sample testing requiring only 0.5–2 µl sample for quick measurements.
  3. 3
    Wide detection capability, offering significantly broader concentration range than traditional spectrophotometers.
  4. 4
    No sample dilution required for most measurements, enabling direct and efficient testing.
  5. 5
    Full wavelength coverage with 190–900 nm scanning and 1 nm accuracy for reliable analysis.
  6. 6
    Automatic optical path switching allowing precise measurement across varying sample concentrations.
  7. 7
    OD600 detection function for monitoring bacterial, yeast and microbial cell growth.
  8. 8
    Fast measurement time (<5 seconds) for rapid laboratory workflows.
  9. 9
    Compact and portable design suitable for laboratory benches and on-site testing.
  10. 10
    Built-in thermal printer and large data storage with USB export for easy data management.
  11. 11
    Intelligent operation system enabling simple and efficient measurement processes.
Where it's used

Applications

  • DNA & RNA Quantification: Accurate measurement of nucleic acid concentration for PCR, sequencing, cloning and other molecular biology workflows.
  • Protein Analysis: Determination of protein concentration in biochemical and proteomics research.
  • Microbial Growth Monitoring: OD600 measurement for analyzing bacterial and yeast culture growth in microbiology laboratories.
  • Clinical & Diagnostic Research: Used in clinical laboratories for biomolecular analysis and disease research studies.
  • Environmental & Food Testing: Detection and analysis of biological samples in environmental monitoring and food safety laboratories.
Nanodrop Spectrophotometer NSP-01

LET'S EQUIP
YOUR LABORATORY

View product online

+1 581 465 8405

www.labotemp.com · info@labotemp.com

144 E, Midwest Avenue, Casper WY 82601, USA