Labotemp Hydrogen Peroxide Plasma Sterilizer LPP-104 delivers low-temperature sterilization for heat- and moisture-sensitive medical and laboratory equipment using hydrogen peroxide vapor/plasma technology. With a 245 L total volume and 203 L effective chamber volume, it operates at 45°C to 55°C, making it suitable for sterilizing compatible instruments that cannot withstand conventional high-temperature steam processes. The system reaches a minimum chamber vacuum level of 55 Pa and uses controlled hydrogen peroxide dosing of 7 mL per detection cycle or 14 mL per standard cycle. Detection mode uses approximately 44 points, while the standard cycle is listed at 71 minutes 30 seconds, supporting efficient routine sterilization workflows.
Designed for demanding healthcare and laboratory environments, the LPP-104 features a rectangular sterilization chamber, four storage levels with a 40 kg total load capacity, swivel casters with brakes, and a 10-inch TFT true-color touchscreen for convenient operation. A built-in dot-matrix printer allows sterilization information to be queried and printed, supporting process documentation and traceability. The system is designed for short-term loading and continuous operation, with a robust chamber and controlled low-temperature process for reliable sterilization performance.
Why Choose Labotemp Hydrogen Peroxide Plasma Sterilizer LPP-104?
✓ Low-Temperature Sterilization: 45°C–55°C operation for suitable heat-sensitive items.
✓ Large 203 L Effective Capacity: Four storage levels support practical batch processing.
✓ Controlled H₂O₂ Process: Precise dosing and vacuum control support consistent sterilization cycles.
| General Specifications | |
| Total Volume | 245 L |
|---|---|
| Effective Volume | 203 L |
| Sterilization Chamber Shape | Rectangle |
| Operating Temperature | 45°C to 55°C |
| Minimum Vacuum Level | 55 Pa |
| Work Schedule | Short-term Loading, Continuous Operation |
| Operating Ambient Temperature | 5°C to 40°C |
| Operating Environment Humidity | 30% to 95% (No Condensation) |
| Operating Atmospheric Pressure | 700 hPa to 1060 hPa |
| Sterilization & Performance | |
| Sterilization Time | Detection Mode 44 Points; Standard Mode 71 Minutes 30 Seconds |
| Hydrogen Peroxide Volume | Detection Mode 7 mL per Time; Standard Mode 14 mL per Time |
| Number of Uses per Cartridge | Detection Mode 6 Times; Standard Mode 3 Times |
| Constant Temperature Power | 2000 W |
| Input Power | ≤4600 W |
| Theoretical Maintenance Cycle | Six Months |
| Chamber & Storage | |
| Sterilization Chamber Dimensions (H×W×D) | 450 × 680 × 800 mm |
| Storage Shelf Dimensions (W×D) | 624 × 760 mm |
| Number of Storage Racks | Four Floors |
| Storage Rack Load Capacity | Total 40 kg, 10 kg per Layer |
| Sterilization Chamber Material | 6061 |
| Shell Material | Q235 |
| Installation Method | Swivel Casters with Brake |
| Minimum Required Installation Dimensions (H×W×D) | 2000 × 2000 × 2000 mm |
| Control & Recording | |
| Display | 10-Inch TFT True Color Touchscreen |
| Printer | Dot Matrix Printer |
| Data Recording and Inquiry | Query and Print at Any Time |
| Dimensions & Weight | |
| Overall Dimensions (H×W×D) | 1785 × 1000 × 1090 mm |
| Packing Dimensions (H×W×D) | 2020 × 1140 × 1240 mm |
| Net Weight | 460 kg |
| Gross Weight | 580 kg |
| Electrical Specifications | |
| Power Supply | 110–220 V, 50/60 Hz 3N~380 V, 50 Hz |
Hospitals & Healthcare Facilities:
Suitable for low-temperature sterilization of compatible heat- and moisture-sensitive medical equipment.
Operating Rooms & Surgical Departments:
Supports sterilization of suitable surgical instruments and equipment that cannot undergo conventional high-temperature steam sterilization.
Medical Device Processing:
Designed for sterilizing compatible medical devices and instruments requiring controlled low-temperature processing.
Laboratories & Research Institutes:
Useful for sterilizing suitable laboratory equipment and materials that are sensitive to high temperatures or moisture.
Pharmaceutical Facilities:
Supports low-temperature sterilization requirements for compatible pharmaceutical and production-related equipment.
Dental & Clinical Facilities:
Suitable for processing compatible heat-sensitive instruments where low-temperature sterilization is required.