Labotemp ELISA Plate Reader LEP-101 is a high-performance Microplate Analyzer designed for accurate and efficient absorbance measurement in clinical diagnostics, research laboratories, and pharmaceutical testing. This advanced ELISA plate reader supports a wide wavelength range of 340–880 nm with single and dual wavelength detection, ensuring precise quantification of biomolecules such as proteins, antibodies, and enzymes. Equipped with a 7-inch touch screen interface, it simplifies operation and data visualization, while high sensitivity and low channel variation ensure consistent and repeatable results across 96-well plates.
Engineered for reliability and long-term use, the system features a stable optical design with high-resolution detection and excellent linearity for dependable performance. The energy-efficient light source extends operational life while reducing maintenance needs. Built-in self-diagnostic functions monitor optical path and system performance, enhancing operational safety and accuracy. With fast reading speeds, robust construction, and user-friendly controls, this ELISA reader is ideal for routine diagnostics, immunoassays, and research workflows requiring precision and efficiency.
Why Choose Labotemp ELISA Plate Reader LEP-101?
✓ High detection accuracy: Dual wavelength for precise results
✓ Wide wavelength range: Supports diverse assay applications
✓ User-friendly operation: Touchscreen interface for easy control
| No. | Specification | Value |
|---|---|---|
| 1 | Ambient Temperature | 4°C – 45°C |
| 2 | Power Supply | AC 100 – 240V, 50/60 Hz |
| 3 | Relative Humidity | ≤ 70% |
| 4 | Channel Difference | ≤ 0.01A (standard filter) |
| 5 | Measuring Speed | Single wavelength <10s/96 wells; Dual wavelength <16s/96 wells |
| 6 | Sensitivity | ≥ 0.010 |
| 7 | Accuracy | (0–2.0) ≤ ±0.005; (2.0–3.0) ≤ ±1%; (3.0–4.0) ≤ ±1.5% |
| 8 | Stability | (0–3.0) ≤ 0.3%; (3.0–4.0) ≤ 1% |
| 9 | Repeatability | (0–3.0) ≤ 0.3%; (3.0–4.0) ≤ 1% |
| 10 | Wavelength Repeatability | ≤ ±1.5 nm |
| 11 | Wavelength Indication Error | ≤ ±3 nm |
| 12 | Linearity | (0–2.0) ≤ ±1%; (2.0–4.0) ≤ ±2% |
| 13 | Resolution | 0.001 Abs |
| 14 | Absorbance Range | 0.000–4.000 Abs |
| 15 | Filter | Standard: 405, 450, 492, 630 nm |
| 16 | Wavelength Range | 340–880 nm |
| 17 | Light Source | 6V 10W halogen lamp |
| 18 | Dimensions (W×D×H) | 280 × 432 × 220 mm |
| 19 | Shipping Size (W×D×H) | 580 × 430 × 360 mm |
| 20 | Net Weight | 8.5 kg |
| 21 | Gross Weight | 13 kg |
Used for quantitative ELISA-based immunoassays including antigen, antibody, protein, and enzyme analysis in clinical diagnostics and biomedical labs. Suitable for multi-wavelength absorbance studies, drug screening, and biomolecular research. Supports quality control testing and routine analysis where precise optical measurement and high-throughput 96-well processing are required.