Labotemp CO₂ Incubator for Cell Culture LCI-101 is a high-performance Laboratory CO₂ incubator engineered to provide precise environmental conditions for mammalian cell culture, tissue engineering, stem cell research, IVF laboratories, microbiology, and pharmaceutical applications. Featuring a 160 L chamber, temperature range from ambient +5°C to 60°C, ±0.1°C temperature accuracy, and an adjustable 0–20% CO₂ concentration, this advanced CO₂ incubator creates a stable environment for reliable cell growth and reproducible experimental results. The six-sided heating system delivers excellent temperature uniformity (±0.4°C at 37°C), while the imported infrared CO₂ sensor continuously monitors gas concentration for accurate control and rapid recovery after door opening.
Built for dependable long-term laboratory operation, the LCI-101 incorporates a 90°C high-temperature sterilization system that helps eliminate bacteria, molds, and mycoplasma, reducing contamination risks between experiments. A 99.99% efficient microbial filter on the CO₂ inlet, natural humidity system with a 4 L water reservoir, and intelligent touchscreen controller further enhance culture reliability. Historical data can be monitored and exported through the USB interface, while audible and visual alarms, real-time operating curves, and fast temperature recovery support safe, efficient, and traceable laboratory workflows.
Why Choose Labotemp CO₂ Incubator LCI-101?
✓ Precise Cell Culture Environment: Six-sided heating with infrared CO₂ sensing ensures stable temperature and gas control.
✓ Enhanced Contamination Protection: 90°C sterilization and 99.99% CO₂ inlet filtration help maintain a clean culture environment.
✓ Intelligent Touchscreen Control: Real-time monitoring, USB data export, and alarm history simplify laboratory operation.
| Capacity | 160 L |
|---|---|
| Temperature Control Range | Room temperature: 5–60°C |
| Power Supply | AC 220 V, 50/60 Hz |
| Temperature Sensor | PT100 |
| Temperature Control Accuracy | ±0.1°C |
| Temperature Control Fluctuation Degree | ≤±0.2°C |
| Temperature Uniformity | ≤±0.4°C (at 37°C) |
| Temperature Recovery Time (1 minute after opening the door) | ≤5 minutes |
| CO₂ Control Range | 0–20% |
| CO₂ Control Accuracy | ±0.1% |
| CO₂ Concentration Sensor | Imported Infrared (IR) Sensor |
| CO₂ Alarm | ≥ ±0.1% (adjustable) |
| CO₂ Intake Filtration Efficiency | 99.99% |
| CO₂ Recovery Time (1 minute after opening the door) | ≤6 minutes |
| Humidification Method | Natural evaporation |
| Relative Humidity | 85% RH |
| Distilled Water Capacity | 4 L |
| Inner Tank Structure | Four curved sides, reservoir-shaped at the bottom |
| Sterilization Method | 90°C high-temperature & high-humidity sterilization / UV ultraviolet disinfection (optional) |
| High-Efficiency Filter at the Air Inlet | 1 |
| Rated Power | 800 W |
| Overall Dimensions (W × D × H) | 675 × 695 × 975 mm |
| Inner Liner Dimensions | 480 × 480 × 698 mm |
| Standard Partition Quantity | 3 pieces |
| Maximum Partition Quantity | 12 pieces |
| Gross Weight | 153kg |
| Package Size | 850 × 750 × 1250 mm |
Designed for cell culture, tissue engineering, stem cell research, IVF laboratories, microbiology, pharmaceutical manufacturing, biotechnology, vaccine development, and academic research. Supports contamination-controlled incubation, microbial cultivation, drug screening, process validation, and quality assurance requiring precise CO₂ and temperature regulation.